[106] Ethernet Receiver 1 Domain Name
Default ( ) Enter the domain name as 32 ASCII characters.
Ethernet Receiver 2 Options
[111] Ethernet Receiver 2 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between transmitters. The account code is used when transmitting
heartbeat signals to the central station receiver. Signals received from the control panel will use the control panel account num-
ber. Valid range: 0000000001- FFFFFFFFFE. Programming all 0 or all F will cause a module configuration trouble (yellow
LED=12 flashes).
[112] Ethernet Receiver 2 DNIS
Default (000000)
The DNIS is used in addition to the account code to identify the communicator module at the central station. Valid range:
000000 - 099999. Value is entered as leading 0 followed by the 5-digit DNIS. Format is BCD.
NOTE: Each Ethernet receiver must be programmed with a unique DNIS.
[113] Ethernet Receiver 2 Address
Default (000.000.000.000)
Programming the Ethernet receiver 2 IP address with 000.000.000.000 will disable Ethernet.
Enter the Ethernet receiver 2 IP address. This address will be provided by the central station system administrator. Format is 4
fields, each field is a 3-digit decimal. Valid range: 000-255.
NOTE: When a valid IP address has been programmed, Ethernet receiver 2 is enabled and will communicate events over the
Ethernet channel.
NOTE: Do not program Ethernet receivers 1 and 2 to communicate to the same receiver.
[114] Ethernet Receiver 2 UDP Remote Port
Default (0BF5/3061)
This section is used to program the port number used by Ethernet receiver 2. Set the value of this port when the installation is
located behind a firewall, and must be assigned a particular port number as determined by the central station system admin-
istrator. Valid range: 0000 - FFFF.
NOTE: Do not program Ethernet receiver 1 and Ethernet receiver 2 port with the same value.
[115] Ethernet Receiver 2 UDP Local Port
Default (0BF9/3065)
Use this section to program the value of the local outgoing port. Set the value of this port when the installation is located behind
a firewall and must be assigned a particular port number as determined by the network administrator. Valid range: 0000 -
FFFF.
NOTE: Do not program Ethernet receiver 1 and Ethernet receiver 2 port with the same value.
[116] Ethernet Receiver 2 Domain Name
Default ( ) Enter the Domain Name as 32 character ASCII.
Ethernet Options
[124] Ethernet Test Transmission Time
Default (9999)
Enter a 4 digit number (0000- 2359) using the 24-hour clock format (HHMM) to set the test transmission time of day. Valid
range: 00 - 23 hours (HH) and 00 - 59 minutes (MM). Programming a value of 9999 will disable the test transmission time.
NOTE: The internal date and time will automatically be programmed when the unit communicates with the primary receiver.
[125] Ethernet Test Transmission Cycle
Default (000000)
This value represents the interval between test transmissions, in minutes. Valid range: 000000 - 999999 minutes. Once the unit
has sent the initial periodic test transmission, all future test transmissions will be offset by the programmed number of minutes.
See sections [026] - [027].
Test Transmission Interval
NOTE: Minimum value is 000005 minutes. Programming an interval that is less than 5 minutes will disable test transmission.
Table 10: Ethernet Test Transmission Interval
Programmed Minutes
Daily
Weekly
001440
010080
17
Monthly
043200