DSC TL280 Installation Manual page 16

Internet alarm communicator - international
Hide thumbs Also See for TL280:
Table of Contents

Advertisement

[030] FTC Restore
Default (FF)
Program 00 to disable this event transmission or FF to enable. This event will occur when an FTC Trouble on the system
restores.
[037] System Firmware Update Fail
Default (FF);
Program 00 to disable this event transmission or FF to enable. This event will occur when the panel firmware updated has
failed.
Event
[037] System FW Update Fail
NOTE: The communicator will report ´System Update Fail´ only if the panel becomes offline after a remote firmware update ses-
sion has started.
[095] SA Incoming Local Port
Default (0000)
[096] SA Outgoing Local Port
Default (0000)
[097] SA Call Up IP
Default (000.000.000.000)
[098] SA Call Up Port
Default (0000)
[099] SA Access Code
Default (FFFFFFFF)
Ethernet Receiver 1 Options
[101] Ethernet Receiver 1 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between transmitters. This account code is used when trans-
mitting heartbeat signals to the central station receiver. Signals received from the panel will use the control panel account num-
ber. Valid range: 0000000001-FFFFFFFFFE. Programming all 0 or all F will cause a module configuration trouble.
[102] Ethernet Receiver 1 DNIS
Default (000000)
The Dialed Number Information Service (DNIS) is used in addition to the account code to identify the communicator module at
the central station. Valid range: 000000 - 099999. Value is entered as a leading 0 followed by the 5 digit DNIS. Format is Bin-
ary Coded Decimal (BCD).
NOTE: Each Ethernet receiver must be programmed with a unique DNIS.
[103] Ethernet Receiver 1 Address
Default (127.000.000.001)
The default address enables the communicator to operate in Unattended Mode.
Unattended mode is used when a receiver is not available and the unit is required to perform DLS sessions. Typically used
where the customer programs the control panel daily due to access control and still wants to receive alarms without buying
extra hardware (receiver) or software.
NOTE: When a valid IP address has been programmed, Ethernet receiver 1 is enabled and will communicate events over the
Ethernet channel.
[104] Ethernet Receiver 1 UDP Remote Port
Default (0BF5/3061)
This section determines the UDP remote port of Ethernet receiver 1. Valid range: 0000 - FFFF.
[105] Ethernet Receiver 1 UDP Local Port
Default (0BF4/3060)
Use this section to set the value of the UDP local outgoing port. Set the value of this port when the installation is located behind
a firewall and must be assigned a particular port number as determined by the central station system administrator. Valid
range: 0000 - FFFF.
Table 9: System Firmware Update Fail
SIA
SIA
Identifier
ReportingCode
LU
0000
16
CID
CID
CID
Event
Reporting
Qualifier
Code
Code
1
9
04
CID
User/Zone
003