HEIL DuraPack 5000 2017 Operation Manual page 191

High-compaction rear loader.
Table of Contents

Advertisement

HEIL CNr
(CONTINUED)
Solenoid Failure Detection
The system is capable of detecting solenoid failures to
open (in the event of a wiring or component issue) when
the ignition is turned ON as per requirement of NFPA 52.
Whenever there is a single solenoid issue, the main screen
will show which solenoid has failed as seen on the figure to
the top right of this page. However, if there are multiple
solenoid issues, it will tell you to go to alarm summary
screen to get more details as seen in the figure to the
bottom right. Alarm Summary Screen
by pressing the right arrow on the display twice.
The figures on this page show example display
screenshots of solenoid failure detection notifications.
Other solenoid failure detection notifications exist and are
not shown here.
To defuel after a solenoid failure on one of the tanks, first
refer to
Solenoid Failure
and then use one of the methods
188
described in CNG Fuel Module Defueling Methods
NOTICE
The audible buzzer will be active only when ignition is ON
and will not turn OFF until the issue is corrected.
Issued September 2017
Compressed Natural Gas (CNG) Option
DuraPack
can be reached
181
.
172
®
5000
Figure 97. Display Screenshot:
Tank 2 Solenoid Failure
Figure 98. Display Screenshot:
Multiple Solenoids Failed
183
Copyright 2017, Heil Environmental