MDS entraNET 900 System Guide (Preliminary)
Table 4-6. Correcting Alarm Conditions
(Alphabetical Order) (Continued)
Event Log Entry
Generating Condition
Invalid IP Address
The IP address is either
0.0.0.0 or 127.0.0.1
MAC Failure
The monitor task reads the
LinkStatus from the MAC
every second. If the MAC
does not reply 10
consecutive times
(regardless of what the result
is) the CPU assumes the
transceiver has lost
communication to the MAC.
Network Interface
Unit does not recognize the
Error
LAN interface
Network Name Not
Network name is "Not
Programmed
Programmed"
PLL Out-of-Lock
The FPGA reports a
synthesizer out-of-lock
condition when monitored by
the CPU.
Power Control
Power control can no longer
Railed High
compensate and reaches the
high rail
Power Control
Power control can no longer
Railed Low
compensate and reaches the
low rail
RSSI Exceeds
The running-average RSSI
Threshold
level is weaker (more
negative) than the
user-defined value.
4.1.6 Logged Non-Critical Events
(See
View Event Log on Page
The following events allow the transceiver to continue operation and do
not make the
POWER
49)
LED blink. Each is reported through an SNMP
Clearing Condition
or Action
IP address is programmed to
something other than 0.0.0.0
or 127.0.0.1 by the user
Contact MDS Technical
Services for assistance
Contact MDS Technical
Services for assistance
Change Network Name to
something other than "Not
Programmed"
Contact MDS Technical
Services for assistance.
Contact MDS Technical
Services for assistance
Contact MDS Technical
Services for assistance
Check aiming of the
directional antenna used at
the Remote; or raise the
threshold level to a stronger
(less-negative) value.