Important Safety Instructions; Intended Use; Power Warning; Warning - lancer IBD 22 Operation Manual

Hide thumbs Also See for IBD 22:
Table of Contents

Advertisement

IMPORTANT SAFETY INSTRUCTIONS

! Intended Use

The dispenser is for indoor use only
This appliance is intended to be used in commercial
applications such as restaurants or similar.
This appliance should not be used by children or
infirm persons without supervision.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety.
This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Cleaning and user maintenance shall not be
performed by children without supervision.
This unit is not a toy and children should be advised
not to play with the appliance.
The min/max ambient operating temperature for the
dispenser is 40°F to 105°F (4°C to 41°C).
Do not operate unit below minimum ambient operation
conditions.
Should freezing occur, cease operation of the unit and
contact authorized service technician.
The maximum tilt for safe operation is 5°.
This appliance must be installed and serviced by a
professional.
5 Carbon Dioxide (CO

WARNING:

Carbon Dioxide (CO2) is a colorless,
noncombustible gas with a light pungent odor. High
percentages of CO
may displace oxygen in the
2
blood.
WARNING:
Prolonged exposure to CO
Personnel exposed to high concentrations of CO
will experience tremors which are followed by a loss
of consciousness and suffocation.
WARNING:
If a CO
gas leak is suspected, immediately
2
ventilate the contaminated area before attempting to
repair the leak.
WARNING:
Strict attention must be observed in the
prevention of CO
gas leaks in the entire CO
2
drink system.
)
2
can be harmful.
2
gas
2
and soft
2
F Power
Follow all local electrical codes when making
connections.
Check the dispenser name plate label, located behind
the splash plate, for the correct electrical requirements
of unit.
DO NOT plug into a wall electrical outlet
unless the current shown on the serial number plate
agrees with local current available.
Each dispenser must have a separate electrical
circuit.
DO NOT use extension cords with this unit.
DO NOT 'gang' together with other electrical devices
on the same outlet.
Always disconnect electrical power to the
WARNING:
unit to prevent personal injury before attempting any
internal maintenance.
The resettable breaker switch should not be used as
a substitute for unplugging the dispenser from the
power source to service the unit.
Only qualified personnel should service internal
components of electrical control housing.
Make sure that all water lines are tight and
WARNING:
units are dry before making any electrical connections
If this dispenser is installed in an area that is
susceptible to ±10% variation of the nominal line
voltage, consider installing a surge protector or similar
protection device.

! Water Notice

Provide an adequate, potable water supply. Water
pipe connections and fixtures directly connected to
a potable water supply must be sized, installed, and
maintained according to federal, state, and local
codes.
The water supply line must be at least a 3/8 inches
(9.525 mm) pipe with a minimym of 25 PSI (0.172
MPA) line pressure, but not exceeding a maximum of
50 PSI (0.345 MPA). Water pressure exceeding 50
PSI (0.345 MPA) must be reduced to 50 PSI (0.345
MPA).
Use a filter in the water line to avoid equipment
damage and beverage off-taste. Check the water filter
periodically, as required by local conditions.
CAUTION:
The water supply must be protected by
means of an air gap, a backflow prevention device
(located upstream of the CO
or another approved method to comply with NSF
standards. A leaking inlet water check valve will
allow carbonated water to flow back through the pump
when it is shut off and contaminate the water supply.
CAUTION:
Ensure the backflow prevention device
complies with ASSE and local standards. It is the
responsibility of the installer to ensure compliance.
injection system)
2
3

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IBD 22 and is the answer not in the manual?

Questions and answers

A.Dravk
March 24, 2025

location and size for counter top cutout under the unit

1 comments:
Mr. Anderson
March 24, 2025

The countertop cutout location and size for the Lancer IBD 22 unit can be found in Section 7 of the manual, which includes illustrations, parts listings, and wiring diagrams.

This answer is automatically generated

Subscribe to Our Youtube Channel

This manual is also suitable for:

4500 seriesIbd 30

Table of Contents