Mitsubishi Electric MELSEC QS SERIES User Manual page 88

Programmable controller cc-link safety system remote i/o module
Hide thumbs Also See for MELSEC QS SERIES:
Table of Contents

Advertisement

6
PROCEDURES AND SETTINGS BEFORE SYSTEM
OPERATION
(4) Wiring example of the QS0J65BTS2-4T (output)
Reserve
I/O24V
connection
14C
protection
24VDC
15C
circuit
I/O24G
16C
17C
Safety
relay
Y0+
2A
Y0-
4A
Load
Safety
relay
Y1+
6A
Y1-
8A
COM-
2C
COM-
13C
Figure 6.19 Wiring example (sink and source outputs)
Reserve
I/O24V
connection
14C
protection
24VDC
15C
circuit
I/O24G
16C
17C
Safety
relay
Y0+
2A
Y0-
4A
Load
Safety
relay
Y1+
6A
Y1-
8A
COM-
2C
COM-
13C
Figure 6.20 Wiring example (source and source outputs)
6
- 25
6.5 Wiring
6.5.6 Safety devices and wiring example
+24V
5VDC
Voltage
conversion
circuit
GND
1000V
+24V
5VDC
Voltage
conversion
circuit
GND
1000V
Insulation
+24V
5
24VDC
24G
7
CC-Link
2000V
dedicated cable
DA
1
DB
2
DG
3
4
SLD
FG
6
Internal
circuit
Insulation
+24V
5
24VDC
24G
7
CC-Link
2000V
dedicated cable
DA
1
DB
2
DG
3
4
SLD
FG
6
Internal
circuit
CC-Link terminal
1
3
5
7
DA
DG
+24V
24G
2
4
6
DB
SLD
FG
Terminal brock
No.
Line C
Line B
1
Empty
2
3
4
5
6
7
COM-
8
9
Empty
10
11
12
13
14
I/O24V
15
16
I/O24G
17
Line A
Empty
Y0+
Empty
Y0-
Empty
Y1+
Empty
Y1-
Empty
Y2+
Empty
Y2-
Empty
Y3+
Empty
Y3-
Empty

Advertisement