5.4.12
RCU II AC Output Wiring
I/O DIGITAL/
I/O 2 METER
ANALOG
METER 0
IO_DA TB1
IO_2M TB3
IN 10
PORT 0 OUT 5
PORT 0
OUT 9
PORT 1 OUT 4
IN
8
PORT 2 OUT 3
PORT 1
OUT 7
PORT 3 OUT 2
IN
6
LINE
IN
PORT 2
OUT 5
IN
4
PORT 3
OUT 3
IN
2
PORT 8
OUT 1
Note: This shows a typical configuration. AC outputs can be assigned to any unused AC output.
METER 1
IO_2M TB2
PORT 0 OUT 5
PORT 0
PORT 1 OUT 4
PORT 2 OUT 3
PORT 3 OUT 2
1
LINE
IN
1
PORT 1
PORT 0.IN/
LINE.IN
PORT 0.OUT
PORT 1.IN/
LINE.IN
PORT 1.OUT
15A
N
N.O.
L
L
C
N.C.
N
L
L
N
N
L
N
48