Air Diverter Installation Instructions; Hanging Installation Instructions - L.B. White Classic 346 Owner's Manual And Instructions

Agricultural animal confinement building heaters
Table of Contents

Advertisement

Available languages

Available languages

Classic Agricultural Animal Confinement Building Heaters
Air Diverter Installation
Instructions
(Must be ordered separately)
1. Air diverters can be installed in the heater outlet
to provide direction to the heated air as it exits the
heater. Installation options include installing the
diverters in such a way as to broadly distribute the air
in two 45 degree paths or to focus the air fl ow in one
45 degree direction. See Fig. 1.
2. The air diverters may require hand forming prior
to installation. Make 90 degree bends utilizing the
perforations provided. Diverters should have the
shape as shown in Fig. 1.
3. The air diverter's tabs on each half will snap into
the blower outlet between the inside of the case as-
sembly and the blower housing outlet. If the notched
tabs do not snap into the blower outlet, loosen (do
not remove) the blower outlet screws. Doing this
provides a gap into which you can insert the tabs.
Retighten the screws after installation.
FIG. 1
(Typical installation allowing two directions of air movement.)
TABS
DIVERTER
HALVES
Alternate Air Diverter Installations:
NOTCHES IN MOUNTING TABS
OUTLET
SCREWS
FORMED
OUTLET GUARD
Hanging Instructions
1. Assemble according to the illustration and tighten
all eyebolts securely. (See Fig. 2):
FIG. 2
EYEBOLT
NUT
FLAT WASHER
CAGE NUT
2. Be sure heater is securely fastened and is hanging
level. (Check crosswise and lengthwise using a
level).
3. See Fig. 3 for typical indoor installation. When
using in an animal confi nement building, consider-
ation must be given to making sure the heater is
located away from the livestock so that livestock
cannot knock the heater, tear it loose from its
mounting, or damage the heater or its gas supply
line in any way. Make sure you observe and obey
minimum clearance distances to combustible
materials as stated in the specifi cation section of
this owner's manual and on the heater itself.
FIG. 3
NOTE: REGULATORS SHOULD ALWAYS BE MOUNTED OUTDOORS. IF
CIRCUMSTANCES FORCE INSTALLING THE REGULATOR INDOORS,
THE REGULATOR'S VENT MUST BE VENTED OUTDOORS USING VENT
LINE NO SMALLER THAN VENT OPENING.
VENT OF REGULATOR MUST
POINT DOWN AND REGULATOR
MUST BE VENTED OUTDOORS
OPTIONAL INDOOR
REGULATOR
MOUNTING LOCATION
GAS HOSE
THERMOSTAT
CORD
YOKE
THERMOSTAT
Owner's Manual • Classic
CHAIN
CASE TOP
MANUAL SHUT-OFF VALVE
CAN BE INSTALLED BEFORE
THE REGULATOR, UNDER
THE EAVE OF THE BUILDING,
OR AFTER THE REGULATOR
INSIDE THE BUILDING.
BLACK PIPE
THROUGH WALL
VENT LINE
WALL OUTLET
HEATER
POWER CORD
SEDIMENT
1 FT. / 0.3m
1 FT.
TRAP
0.3m
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents