Air Diverter Installation Instructions; Hanging Instructions - L.B. White AW250 Owner's Manual And Instructions

Agricultural animal confinement building heaters
Table of Contents

Advertisement

(Appearance of the outlet on heater may vary from model to model.)
1. Air diverters can be installed in the heater outlet to
provide direction to the heated air as it exits the
heater. Refer to Fig. 1. Air diverters can be installed to
direct the air in either two 45 degree paths or in one
45 degree direction.
2. The air diverters may require hand forming prior to
installation. Make 90 degree bends utilizing the
perforations provided. The diverter halves should
then have the shape as shown in Fig. 1.
3. The air diverter's tabs on each half will pop into the
blower outlet between the inside of the case
assembly and the blower housing outlet. If the
notched tabs do not pop into the blower outlet, loosen
the blower outlet screws. Doing this provides a gap
into which you can insert the tabs. Retighten the
screws after installation.
1. Assemble according to Fig.3 and tighten all eyebolts
securely.
2. Be sure heater is securely fastened and is hanging
level. (Check crosswise and lengthwise.)
3. See Fig. 2 for typical indoor installation. In any animal
confinement building, consideration must be given to
making sure the heater is located away from the
livestock so that livestock cannot knock the heater,
tear it loose from its mounting, or damage the heater
or its gas supply line in any way. Make sure you
observe and obey minimum clearance distances to
combustible materials as stated in the specification
section of this owner's manual and on the heater
dataplate.
FIG. 3
EYE BOLT
NUT
FLAT WASHER
FLAT WASHER
NUT

AIR DIVERTER INSTALLATION INSTRUCTIONS

CHAIN
HEATER TOP
FIG.1
(Typical installation allowing two directions of air movement.)
TABS
DIVERTER
HALVES
ALTERNATE AIR DIVERTER ARRANGEMENTS

HANGING INSTRUCTIONS

FIG. 2
NOTE: REGULATORS SHOULD ALWAYS BE MOUNTED OUTDOORS. IF
CIRCUMSTANCES FORCE INSTALLING THE REGULATOR INDOORS,
THE REGULATOR'S VENT MUST BE VENTED OUTDOORS USING VENT
LINE NO SMALLER THAN VENT OPENING.
VENT OF REGULATOR MUST
POINT DOWN AND REGULATOR
MUST BE VENTED OUTDOORS
OPTIONAL INDOOR
REGULATOR
MOUNTING LOCATION
GAS HOSE
THERMOSTAT
CORD
YOKE
AIR DIVERTER
.3 m
THERMOSTAT
NOTCHES IN MOUNTING TABS
OUTLET
SCREWS
FORMED
OUTLET GUARD
MANUAL SHUT-OFF VALVE
CAN BE INSTALLED BEFORE
THE REGULATOR, UNDER
THE EAVE OF THE BUILDING,
OR AFTER THE REGULATOR
INSIDE THE BUILDING.
BLACK PIPE
PIPE THROUGH WALL
THROUGH WALL
VENT LINE
WALL OUTLET
HEATER
POWER CORD
SEDIMENT
1 FT.
TRAP
1 FT.
.3 m
9