connections, hose connections, fi ttings and joints
as well as the gas control valve inlet and outlet
connections with approved gas leak detectors.
-- If a leak is detected, check the components
involved for cleanliness in the thread areas and
proper application of pipe compound before
further tightening.
-- Tighten the gas connection as necessary to stop
the leak.
-- If necessary, replace the parts or components
involved if the leak cannot be stopped.
-- Ensure all gas leaks have been identifi ed and
repaired before proceeding.
12. A qualifi ed service agency must check for proper
operating gas pressure upon installation of the
heater.
13. Light according to instructions on heater or
within owner's manual.
14. It is extremely important to use the proper size
and type of gas supply line to assure proper
functioning of the heater. Contact your fuel gas
supplier for proper line sizing and installation
15. Ensure the heater has the proper gas regulator
for the application. A regulator must be con-
nected to the gas supply so that gas pressure
at the inlet to the gas valve is regulated within
the range specifi ed on the dataplate at all times.
Contact your gas supplier, or the L.B. White Co.,
Inc. if you have any questions.
16. This heater can be confi gured for use with either
L.P. gas vapor withdrawal or natural gas. Con-
sult the dataplate for the gas confi guration of the
specifi c heater. Do not use the heater in an L.P.
gas liquid withdrawal system or application. If
you are in doubt, contact the L.B. White Co., Inc.
17. Eventually, like all electrical/mechanical devices,
the thermostat can fail. Thermostat failure may
result in either an underheating or overheating
condition which may damage critical products
and/or cause animal injury or death. Critical
products and/or animals should be protected by
Owner's Manual • Classic
a separate back-up control system that limits
high and low temperatures and also activates
appropriate alarms.
18. Take time to understand how to operate and
maintain the heater by using this Owner's
Manual. Make sure you know how to shut off
the gas supply to the building and also to the
individual heater. Contact your fuel gas supplier
if you have any questions.
19. Any defects found in performing any of the
service or maintenance procedures must be
eliminated and defective parts replaced immedi-
ately. The heater must be retested by properly
qualifi ed service personnel before placing the
heater back into use.