Guardian agricultural animal confinement building heaters (31 pages)
Summary of Contents for L.B. White 346
Page 1
Your new L.B. White heater incorporates the benefits from the most experienced manufacturer of heating products using state-of-the-art technology. We, at L.B. White, thank you for your confidence in our products and welcome any suggestions or comments you may have...call us, toll-free, at 1-800-345-7200.
Page 3
Save this Owner’s Manual for future use and reference. Owner’s Manuals and replacement labels are available at no charge. For assistance, contact L.B. White at 800-345-7200. WARNING Proper gas supply pressure must be provided to the inlet of the heater.
The dateplate is located on the exterior of the burner end panel. Contact your local L.B. White distributor or the L.B. White Co., Inc. for assistance, or if you have any questions about the This manual will instruct you in the operation and care of use of the equipment or its application.
Heater Specifications M M o o d d e e l l SPECIFICATIONS Fuel Type L.P. Gas Natural Gas Maximum Input (BTUH) 60,000 Ventilation Air Required 250 CFM to Support Combustion 13.5 in. MAX. Inlet Gas Supply Pressure Acceptable W.C. at the Inlet of the Heater for Purpose MIN.
Symptoms of carbon monoxide poisoning can include headaches, dizziness and difficulty in breathing. Refer to the specification section of the heater’s Owner’s Manual, heater dataplate, or contact the L.B. White Symptoms of improper combustion affecting livestock can be disease, lower feed conversion, or death.
Page 7
2. All installations and applications of L.B. White heaters 11. This heater should be inspected for proper operation must meet all relevant local, state and national codes. by a qualified service person before building Included are L.P.
Installation Instructions GENERAL Any heater or appliance connected to a piping system WARNING must have an accessible, approved manual shut off Fire o o r e e xplosion h h azard. valve installed within six feet (6 ft.) of the appliance it Can c c ause p p roperty d d amage, s s evere i i njury o o r d d eath.
Contact your gas supplier, or and also to the individual heater. Contact your fuel the L.B. White Co., Inc. if you have any questions. gas supplier if you have any questions. 13. This heater can be configured for use with either L.P.
HANGING INSTRUCTIONS FIG. 3 1. Assemble according to the illustration and tighten all eyebolts securely. (See Fig. 2): NOTE: REGULATORS SHOULD ALWAYS BE MOUNTED OUTDOORS. IF FIG. 2 CIRCUMSTANCES FORCE INSTALLING THE REGULATOR INDOORS, THE REGULATOR'S VENT MUST BE VENTED OUTDOORS USING VENT LINE NO SMALLER THAN VENT OPENING.
THERMOSTAT INSTALLATION 2. To C C onnect t t he D D irect W W ired T T hermostat K K it t t o t t he WARNING Junction B B ox o o n t t he H H eater: Electrical S S hock H H azard a.
Start-Up Instructions ATTENTION Follow steps 1 - 8 on initial start-up after heater installation by a qualified gas heater service person. For normal start- up, simply turn thermostat above room temperature. The On new installations it may take a short period of time for the heater will start.
Cleaning Instructions WARNING Fire, B B urn, a a nd E E xplosion H H azard This heater contains electrical and mechanical components in the gas management, safety and airflow systems. Such components may become inoperative or fail due to dust, dirt, wear, aging, or the corrosive atmosphere of an animal confinement building.
Electrical Connection and Ladder Diagram CAUTION Always refer to the heater’s electrical connection diagram when servicing to avoid wiring errors and heater malfunction. Check for proper operation after servicing. WARNING: THIS HEATER MAY START AT ANY TIME AIR PROVING SWITCH (NOT SUPPLIED ON SOME MODELS) BLACK OR RED...
Heater Component Function Burner Pilot Light Orifice Cast iron component used to channel gas and provide an A metering device used to supply gas for the dual purpose of area at which the fuel may ignite. igniting the main burner and heating the thermocouple. Burner Orifice Pilot Safety Control Valve Brass metering device used to feed gas to burner at a...
PARTS LIST Item Description Part N N umber Regulator, S S ingle S S tage ( ( LP G G as) 550-0 0 6772 Regulator, S S econd S S tage ( ( LP G G as) 130-0 0 6669 Bushing 3 3 /8 N N PT x x 1 1 /4 130-0 0 1544 Hose, 1 1 /4 i i n.
Warranty Policy EQUIPMENT L.B. White Co., Inc. warrants that the component parts of its or replace the defective part or heater, with a new part or heater are free from defects in material and workmanship, heater, F.O.B., Onalaska, Wisconsin. when properly installed, operated, and maintained in accordance with the Installation and Maintenance A warranty card on file at L.B.
Need help?
Do you have a question about the 346 and is the answer not in the manual?
Questions and answers