SPECIFICATIONS

Copier and Main unit

Type
Print system
Exposure system
Developer system
Paper feed system
Fusing system
Resolution
Gradation
Originals
Copy paper
Copy sizes
Warm-up time
First-copy time*
Copy ratio
Continuous copy
Expansion DIMM slot
Dimensions
Weight (main unit only)
Overall dimensions
Required power supply
Power consumption
Operating conditions*
* The indicated first-copy time assumes the following conditions:
Upper tray at paper intake / horizontal feeding of A4 size paper / no pre-scan / left output tray/ transfer belt: black copy position
The first-copy time is slower when making copies on transparency film, heavy paper, or other special paper in the
bypass tray.
8-2
Desktop (can be upgraded to console type if an optional stand is installed.)
System (LED head system)
OPC
Contact non-magnetic single-component development
Paper trays
Press rollor fusing method
Scan: 600 x 600 dpi, output: 600 x 600 dpi
Scan:
256 levels, output: 2 levels
Printing: Color: Equivalent of 256 levels / Black and white: 2 levels (in copy mode)
/ Equivalent of 256 levels (in printer mode)
Sheets, bound documents
Maximum size: 11" x 17" or A3
Plain paper and special papers
Max. 12" x 18" or A3wide, min. 5-1/2" x 8-1/2" or A5
Image loss: Max. 1/4" or 6 mm (leading edge and trailing edge in total),
max. 1/4" or 6 mm (along all other edges in total)
99 seconds or less
Full color/single color copying : 8.0 seconds or less
Black/white copying : 7.0 seconds or less
Variable: 45 to 400% in 1% increments, total 356 steps
Fixed presets: 25%, 50%, 64%, 77%, 100%, 121%, 129%, 200% and 400% for
inch system, 25%, 50%, 64%, 70%, 81%, 86%, 100%, 115%, 122%, 141%, 200%
and 400% for AB system.
999 copies; subtractive counter
1 slot (128 MB or 256 MB can be installed)
26-25/64" (W) x 26-5/8" (D) x 27-59/64" (H) (670 mm (W) x 676 mm (D) x 709 mm (H))
AR-C260 : Approx. 143.4 lbs. (Approx. 65kg)
AR-C260M : Approx. 147.8 lbs. (Approx. 67kg)
39-9/64" (W) x 26-5/8"(D) (994 mm (W) x 676 mm (D))
USA: AC120V, 60Hz, 12A
Other countries: Local voltage
name plate located on the right hand side at the rear of the main unit.)
Max. 1.5 kW
Temperature: 59°F to 86°F (15°C to 30°C),
Humidity: 20% to 80%
* If the temperature is higher than 86°F (30°C), the humidity should be lower than
60%.
±
10% (For power supply requirements, see the