Danfoss VLT AQUA Drive FC 202 Operating Instructions Manual page 16

315-1400 kw
Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

Mechanical Installation
Enclosure size
3
3
High overload rated
power - 160%
overload torque
IP
NEMA
Shipping
dimensions
[mm]
Drive
dimensions
Table 3.4 Mechanical Dimensions, Enclosure Sizes E and F
NOTICE
The F frames are available in 6 different sizes, F8, F9, F10, F11, F12 and F13 The F8, F10 and F12 consist of an inverter
cabinet on the right and rectifier cabinet on the left. The F9, F11 and F13 have an additional options cabinet left of the
rectifier cabinet. The F9 is an F8 with an additional options cabinet. The F11 is an F10 with an additional options
cabinet. The F13 is an F12 with an additional options cabinet.
14
F8
F9 F8
315 - 450 kW
(380 - 500 V)
400 - 630 kW
(525-690 V)
21, 54
Type 12
Height
2324
Width
970
Depth
1130
Height
2204
Width
800
Depth
606
Max
weight
440
[kg]
Danfoss A/S © Rev. 06/2014 All rights reserved.
Operating Instructions
F9
F10
F11
F10
500 - 710 kW
(380 - 500 V)
710 - 900 kW
(525-690 V)
21, 54
Type 12
2324
2324
1568
1760
1130
1130
2204
2204
1400
1600
606
606
656
880
F11
F12
F13
F12
800 - 1000 kW
(380 - 500 V)
1000 - 1400 kW
(525-690 V)
21, 54
Type 12
2324
2324
2559
2160
1130
1130
2204
2204
2200
2000
606
606
1096
1022
F13
2324
2960
1130
2204
2600
606
1238
MG20Y202

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT AQUA Drive FC 202 and is the answer not in the manual?

Questions and answers

Table of Contents