INSTALLATION CONNECTIONS
LTR
DESCRIPTION
H1
Hot Water to Final Rinse - 180
H2
Hot Water to Remote Booster
H3
Hot Water to Steam Booster
H4
Hot Water to Built-In Booster
S1
Steam to Tank
S2
Steam to Steam Booster
D
Drain Connection - Common
D1
Drain Cool Down Connection (Optional)
R1
Condensate Return - Steam Booster
R2
Condensate Return - Tank Coil
E1
Electric Service - Washer Motors & Built-In Booster
E2
Electric Service - Remote Booster
Commander 18-6 Technical Manual 2018
®
F
1/2" FIPS
O
1/2" FIPS
1/2" FIPS
1/2" FIPS
1/2" FIPS
1/2" FIPS
1 1/2" CU NOM
3/4" IPS
1/2" FIPS
3/8" FIPS
PART 2 INSTALLATION INSTRUCTIONS
Installation Drawing : Commander 18-6
SIZE
*
for ELECTRIC HEAT (3PH/60Hz), add the following:
Heat Element
Built-In Booster
**
12 kW when specified
NOTES:
1.
Wash Tank is filled through Final Rinse Line
2.
Washer is field-convertible from Straight to Corner
configuration
*
1 HP
**
6 kW
www.insingermachine.com
10
208 V
240 V
380 V
5.0 kW
5.0 kW
5.0 kW
10.1 kW
13.5 kW
13.5 kW
REV F - 07/08/11
800-344-4802
480 V
5.0 kW
13.5 kW