10. TECHNICAL DATA

Protig 410
Working voltage (safety voltage)
Rated power
Max. load
60 % ED
100 % ED
Pressure endurance of gas hose
Connection of gas hose
Welding cable connectors
Torch connection (adapter)
Operation temperature range
Storage temperature range
Temperature class
Degree of protection¹)
Dimensions
Weight
The product meets conformity requirements for CE marking.
IP 34 means that the device is protected against water coming from any direction, directly or
1)
splashing.
Control panels
Main operations of Protig 410 panels TL and TX are in enclosed table.
Spark ignition
Contact ignition
2 function / 4 function torch operation
Fusion point timer
Pulsing
Minilog operation
Up-slope timer for current
Down-slope timer for current
Selectotig memory channels
Current display (digital)
22 – PROTIG 410 / 0537
50 VDC
50 W
400 A
310 A
600 kPa max.
snap connector
DIX 70
Multi-function
-20...+40 °C
-40...+60 °C
B (130 °C)
IP 34
length
615 mm
width
260 mm
height
400 mm
17 kg
TL 6271265
yes
yes
yes
--
--
--
yes
yes
--
yes
TX 6271266
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes