KEMPOTIG AC/DC
KEMPOTIG AC/DC
1916130
KEMPOTIG 4500 AC/DC
Lue ja perehdy tähän ohjeeseen ennen hitsauskoneen käyttöönottoa !
Läs noga igenom denna bruksanvisningen före bruket av svetsmaskinen !
Read carefully these instructions before you use the welding machine !
Bitte, lesen Sie diese Gebrauchsanweisungen vor Gebrauch der Schweiß-
maschine !
Lees deze gebruiksaanwijzing aandachtig door voor u de lasmachine in
gebruik neemt !
Veuillez lire et appliquer ces instructions avant utilisation de la machine !

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KEMPOTIG 4500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kemppi KEMPOTIG 4500

  • Page 1 KEMPOTIG AC/DC KEMPOTIG AC/DC 1916130 KEMPOTIG 4500 AC/DC Lue ja perehdy tähän ohjeeseen ennen hitsauskoneen käyttöönottoa ! Läs noga igenom denna bruksanvisningen före bruket av svetsmaskinen ! Read carefully these instructions before you use the welding machine ! Bitte, lesen Sie diese Gebrauchsanweisungen vor Gebrauch der Schweiß-...
  • Page 4 V1 R1 F3, F4...
  • Page 5 Verkkokaapelin kytkentä Anslutning av nätkabel Connection of mains cable Anschluss des netzkabels Aansluiting van netkabel Raccordement du câble d’alimentation Pölysuotimen irroitus Lossning av dammfiltret Removal of dust filter Lösung des Staubfilters Verwijderen van stoffilter Changement du filtre antipoussière...
  • Page 6 Kempotig 4500 AC/DC Kempotig 4500 AC/DC...
  • Page 7 Kempotig 50 WU 10 Kempotig 4500 AC/DC Kempotig 50 WU 10...
  • Page 8 C 100C Kempotig 50 GH 20 TTM 25 Kempotig WU 10 4500 AC/DC T2 ..............6185235 T50 ..............6185245 WU 10 ............6262010 Kempotig 4500 AC/DC ......... 6164500 Kempotig 50 ..........6271224 GH 20 ............6256020 C 100C ............6185410...
  • Page 9 C 100C, C 100D C 100P R min R max C 100F Pitkäpulssisäädin TIG-hitsaukseen Jalkapoljinsäädin TIG-hitsaukseen Långpulsreglage för TIG-svetsning Fotpedalreglage för TIG-svetsning Long pulse unit for TIG welding Foot pedal control unit for TIG welding Langpulsregler für WIG-Schweißen Fußpedalregler für WIG-Schweißen Pulsregeling voor TIG-lassen Voetpedaalregeling voor TIG-lassen Unité...
  • Page 10 Mittariyksikkö MU 20D Mätarenhet MU 20D Meter unit MU 20D Messereinheit MU 20D Meterunit MU 20D Afficheur digital MU 20D MU 20D Huom! Achtung! MU 20D MU 20D OBS! MU 20D LET OP! MU 20D Note! MU 20D REMARQUE!
  • Page 11 C 100C ............6185410 C 100D ............6185413 C 100P ............6185424 C 100F ............6185405 PSM 10 ............6185651...
  • Page 13: Operation Safety

    Watch out for the fire and explosion danger when welding container type work pieces. TERMS OF GUARANTEE KEMPPI OY provides a guarantee for products manufactured and sold by them if defects in manufacture and materials occur. Guarantee repairs must be carried out only an Authorized KEMPPI Service Agent. Packing, freight and insurance costs to be paid by third party.
  • Page 14: Operation

    GENERAL Tolerance of the mains supply voltage The Kempotig 4500 AC/DC was designed to operate The Kempotig 4500 AC/DC is a multi-purpose power from a standard 380...415 V (50 / 60 Hz) supply without source baced on inverter techniques. The Kempotig any alterations or adjustments in connections to the machine.
  • Page 15 ASSEMBLY AND OPERATION OF The balance control doesn’t change the frequency of alternating current (AC). WELDING EQUIPMENT The balance control is in operation both in AC-TIG- and AC-MMA welding and the control is indicated by the green The cable connection of the welding equipment combi- signal light V1.
  • Page 16: Operation Disturbances

    In the case of operation disturbances, contact an au- type and rating which is marked on collar of fusebox. thorized KEMPPI Service Repair Shop. Check the main- Damage caused by a wrong type fuse, is not covered by tenance parts before sending the machine to the serv- the guarantee.
  • Page 17: Technical Data

    TECHNICAL DATA Kempotig 4500 AC/DC Connection voltage 3 ~, 50 / 60 Hz 400 V Rated power 60 % ED 26,3 kVA 100 % ED 22,8 kVA Maximum load 80 % ED 450 A / 38 V 100 % ED...

Table of Contents