Control Ranges For Time And Per Cent; Demo: Learning And Control State - Kemppi Protig 410 Operation Instructions Manual

Table of Contents

Advertisement

In panel TX there are also following operation and controls:

Demo: learning and control state

Controls for continuous welding
Controls for pulsed TIG welding
Controls for fusion spot welding
Minilog-function and control of start current
Breaking the down-slope operations
Program storing of selectotig

3.2.1. Control ranges for time and per cent

Pre-gas time
Current up-slope time
Start current
Minilog basic current
Pulse ratio
Length of cycle
Pause current of pulse
Spot welding time
Current down-slope time
Post gas time
Minilog pressing:
Per cent values of table are calculated from control value.
3.2.2. Demo: Learning and control state
In demo state coming of ignition spark and gas are stopped. All other controls ope-
rate as during welding. Basic controls for current, times and per cent can be carried
out safely in this state and after that you can go over to welding using either spark
or contact ignition.
Use arrow keys when you go over to control different functions. You can go to
available controls by selected welding mode. It is indicated by pilot lamp, in which
stage of operation flow chart you are now and which parameters can be controlled
by you.
© KEMPPI OY
0...9 s
0...9 s
30...150 %
10...90 %
10...80 %
0,002...4 s (max. 500 Hz)
10...80 %
0...9 s
0...30 s
0...99 s
short
less than 0,7 s
long
more than 0,7 s