Figure 29. Moving a Chassis onto a Rack or Cabinet
60
SAN192C-6, SAN384C-6 and SAN768C-6 Installation, Service, and User Guide
first, and push until the chassis is halfway onto the rack (see the following
figure). Ensure that the chassis does not get caught on any of the expansion
edges of the bottom-support rail.
1. Push the sides of the lower half of the front side of the chassis.
2. Push the chassis into the rack until its mounting bracket touches the
vertical mounting rails on the rack.
Tip: To adjust the placement of the chassis on the bottom-support rails, you
can use the handles on the sides of the chassis.
5. If the mechanical lift is raised above the height of the bottom-support rails,
gently lower it to the level of the rails or no more than 1/4 inch (0.6 cm)
below the rails. This action helps to prevent the bottom of the chassis from
getting caught on the bottom expansion edges of the bottom-support rails.
6. Push the chassis all the way onto the rack so that the vertical mounting
brackets on the chassis come in contact with the vertical mounting rails on the
rack.
7. Use seven M6 x 19 mm or 24 x 3/4-inch screws to attach each of the two
vertical mounting brackets on the chassis to the two vertical mounting rails on
the rack (total of 14 screws). See Figure 30 on page 61.