Table 22 lists the specifications for the IBM c-type SAN Director 48-Port 32-Gbps
FC Switching Module.
Power Specifications for the IBM c-type SAN Director
This section includes the following topics:
v "Power Supply Specifications"
v "Component Power Requirements and Heat Dissipation" on page 103
v "AC Power Consumption for the SAN768C-6 Director" on page 105
v "AC Power Consumption for the SAN384C-6 Director" on page 105
v "AC Power Consumption for the SAN192C-6 Director" on page 106
v "AC Power Supply Requirements for Grid Redundancy" on page 106
Power Supply Specifications
Table 23 lists the specifications for the SAN c-type Director power supplies.
102
SAN192C-6, SAN384C-6 and SAN768C-6 Installation, Service, and User Guide
Table 21. Extension Module Specifications (continued)
Description
Dimensions
Weight
Table 22. IBM c-type SAN Director 48-Port 32-Gbps Fibre Channel Switching
Module Specifications
Description
Environmental Requirements
Temperature, certified for operation (module
intake of ambient)
Temperature, ambient nonoperating and
storage
Humidity (RH), ambient (noncondensing)
operating
Altitude, designed and tested for operation
Physical Characteristics
Dimensions
Weight
Table 23. SAN c-type Director Power Supplies
Description
3000-W AC Power Supply
Type
Voltage
Current rating
Specification
1.75 x 15.9 x 21.8 in. (4.4 x 40.39 x 55.37 cm)
17 lb (7.7 kg)
Specification
32 to 104° F (0 to 40° C)
-40 to 158° F (-40 to 70° C)
10 to 90%
-197 to 6500 ft (-60 to 2000 m)
1.75 x 15.9 x 21.8 in. (4.4 x 40.39 x 55.37 cm)
17.5 lb (7.94 kg)
Specification
Autoranging input with power factor
corrector.
100 to 240 VAC (+ or - 10%).
16 A maximum at 100 to 120 VAC and
1451-W output. 16 A maximum at 200 to 240
VAC and 3051-W output.
For current ratings of plugs, see Figure 42 on
page 116.