10. If you removed any power supplies before moving the chassis, reinstall each
70
SAN192C-6, SAN384C-6 and SAN768C-6 Installation, Service, and User Guide
Note: If there are only three fabric modules to install, install them in fabric
slots 1, 3, and 5, and be sure that there are blank filler plates installed in
the open slots.
c. Slide the module part way into the slot.
d. Press the ejector button on the front of the module, to release the levers
from the front of the module.
e. Rotate the levers away from the front of the module and hold them while
sliding the module all the way into the slot.
f. Simultaneously rotate both levers to the front of the module. They click
when locked to the front of the module.
9. If you removed any fan modules before moving the chassis, reinstall each one
in the chassis as follows:
a. Holding each of the two handles on the fan module with your two hands,
align the fan module to an open fan module slot.
Note: The two alignment brackets on top of the fan module should align
to two tracks at the top of the slot.
b. Slide the fan module into the slot until the front of the fan module comes
in contact with the rear of the chassis.
Note: The two alignment pins on the fan module (on the top and one on
the bottom) should go into holes in the chassis and the four captive screws
on the fan module should align to screw holes in the chassis.
c. Screw in the four captive screws to the chassis and tighten each screw to 8
in-lb (0.9 N-m).
one as follows:
a. Determine which power supply slots to fill and ensure that each of those
slots is open.
b. If you are using the combined or power supply redundancy mode, you
can use any slot for the power supply that you are installing.
If you are using input-source or full redundancy mode, you must group
the power supplies that are to be connected to the same grid on either the
left or right power supply slots in the chassis (that is, place the power
supplies for grid A in slots 1 or 2 or both slots and place the power
supplies for grid B in slots 3 or 4 or both slots).
c. Place one hand on the front of the power supply and place your other
hand under it to support its weight.
d. Align the power supply to an open power supply slot.
Note: The alignment bracket on top of the power supply should align to a
track at the top of the slot and a bar at the bottom of the power supply
should be guided by a track at the bottom of the slot.
e. Slide the power supply all the way into the slot until it stops.
f. Slide the handle in the middle of the ejector lever toward the end of the
lever and rotate the lever to the front of the power supply. Release the
middle handle.
Note:
v The lever should grab the inside of the slot and push the power supply
onto its mid-plane connectors.