Considerations
All illustrations used in the procedure are for example purposes only.
To unassign an IOC from an IOM using the Function Block Assignment Dialog box,
perform the following steps.
Step
1
Double-click given CM in the Project tree.
Right-click the IOC channel block.
2
Select Function Block Unassign
3
Click to clear the box for desired channel in given
IOM.
4
Click Assign.
5
Click the dialog close button to complete the
assignment.
6
Click Yes to accept the changes.
6.6

Defining Channel blocks

Overview

Each Series 8 I/O channel (IOC) block represents a single I/O point within an I/O module
(which can be either input or output). There are certain attributes and parameters that are
common to all I/O channel blocks. The Series 8 IOC block has a point execution state.
This allows for easy reconfiguration of a single channel without disrupting the operation
of the entire IOM.
Each IOC block must have an "assignment" block and "containment" block in order for it
to be loadable. The following table describes these blocks.
R500
April 2017
Action
Series 8 I/O User's Guide
Honeywell
6. Series 8 I/O Configuration
6.6. Defining Channel blocks
Results
Opens CM in control
chart area.
Opens shortcut
menu.
Opens Function
Block Assignment
Dialog box that list
compatible IOCs
associated with the
IOM assigned to an
IOLINK.
Clears the check
mark.
Unassigns the
selected IOC block.
Confirmation dialog
box appears.
Function Block
Assignment Dialog
box closes.