Mechanical Installation
VLT
Drive Motor
www.danfoss.com
MADE IN DENMARK
1
T/C: FCM106P7K5T4C55H1FSXXAXXE4N7K5150B03000
15
3
3
14
13
Out: 7.5kW(400V) / 10HP(460V)
12
Tamb. 40 C/104 F
11
MOTOR REF: HPS112 1500 159
10
0-1500 min /50Hz
DBV: &OEM3&
Type code
1
2
Certifications
3
Enclosure rating
4
Serial number
5
Motor duty class
6
Certifications
7
Weight
8
Motor power factor
9
Enclosure rating - Ingress protection (IP) class
10 Frequency range
11 Motor reference
12 Maximum ambient temperature
13 Power rating
14 Input voltage, current, and frequency (at low/high voltages)
15 Ordering number
Illustration 3.2 FCM 106 Nameplate (Example)
1): Example of format: Serial number 'xxxxx253' indicates
manufacture in week 25, year 2013
NOTICE
Do not remove the nameplate from the frequency
converter (loss of warranty).
10
Listed E347257
EP Motors for Ind. Use
Enclosure rating Type 12
P/N: 134L4306
S/N: 000000G000
IN: 3X380-480V, 50-60Hz, 15/13A
o
o
IP55
DUTY Class S1
Wt 14.5 kg
-1
Cos /PF: 0.98 / 0.96
MSV: &OEM4&
1)
Danfoss A/S © Rev. 06/2014 All rights reserved.
Operating Instructions

3.1.6 Lifting

2
NOTICE
3
LIFTING - EQUIPMENT DAMAGE RISK
4
Incorrect lifting can result in equipment damage.
5
6
Handling and lifting of the unit must only be undertaken
9
8
7
by qualified personnel. Ensure
Eyebolts or lifting trunnions supplied with the unit are
rated to bear the weight of the unit only, not the
additional weight of ancillary equipment attached.
3.1.7 Storage
Ensure that requirements for storage are fulfilled. Refer to
chapter 7.5 Ambient Conditions for further details.

3.2 Installation Environment

NOTICE
In environments with airborne liquids, particles, or
corrosive gases, ensure that the IP/Type rating of the
equipment matches the installation environment. Failure
to meet requirements for ambient conditions can reduce
lifetime of the frequency converter. Ensure that
requirements for air humidity, temperature and altitude
are met.
Vibration and Shock
The frequency converter complies with requirements for
units mounted on the walls and floors of production
premises, as well as in panels bolted to walls or floors.
For detailed ambient conditions specifications, refer to
chapter 7.5 Ambient Conditions.
Use both lifting lugs when provided.
For vertical lift, prevent uncontrolled rotation.
For lift machine, do not lift other equipment
with motor lifting points only.
availability of full product documentation,
together with tools and equipment necessary for
safe working practice.
cranes, jacks, slings, and lifting beams are rated
to bear the weight of equipment to be lifted. For
weight of unit, see chapter 7.1.4 Weight.
when using an eyebolt, that the shoulder of the
eyebolt is tightened firmly against the face of the
stator frame, before lifting.
MG03L202