SSD Parvex DIGIVEX Little Drive Servoamplifier User And Commissioning Manual page 84

Table of Contents

Advertisement

DIGIVEX Little Drive Servoamplifier
DEFAULT
TYPE
Excessive mean
or
7
rms
current
Bus overvoltage
8
Excessive
motor
9
temperature
Recovery fault
r
This manual was downloaded on www.sdsdrives.com
+44 (0)117 938 1800 - info@sdsdrives.com
Mean current: measurement of the mean current supplied by the motion controller
Rms current: calculation of the rms current supplied by the motion controller
Causes:
Oversized operating cycle
Mechanical binding spot
Braking recovery impossible
Causes:
Oversized operating cycle
Motion controller braking capacity much too low with regard to the application
Causes:
Check connections
The motor is confined and cannot cool down
Motor does not have a temperature sensor: this sensor was not acknowledged during
customization.
Causes:
Cycle too restricting
Axis recovery capacity exceeded.