Braking Capacity And Module Losses - SSD Parvex DIGIVEX Little Drive Servoamplifier User And Commissioning Manual

Table of Contents

Advertisement

DIGIVEX Little Drive Servoamplifier

2.1.3 Braking capacity and module losses.

230 V single-phase or three-phase modules.
Resistor value
Maximum current
Pulse power
Permanent power
Maximum non repetitive duration
Repetition
Losses from modules (at
maximum power)
Low level consumption
Definitions
Maximum power: Maximum power drawn, resistance connecting is carried out at 360V, hence,
the power drawn has a maximum resistance value equal to 360.
Pulse power: maximum power dissipated by the resistor, this power can only be drawn for a
short time and in compliance with a certain cycle.
Permanent power (to 25°C) : mean power that can be dissipated on a permanent basis by the
resistor.
Maximum duration: maximum duration, in seconds, for which the pulse power can be required
(starting from cold); the resistor must be allowed to cool down before braking again.
Module losses: losses specific to the module, the value shown in the table is that obtained when
the module is used at maximum power.
Low-level consumption: consumption of the low-level power supplies in Watts.
This manual was downloaded on www.sdsdrives.com
+44 (0)117 938 1800 - info@sdsdrives.com
18
PVD 3530 GB 01/2005
MODULE RATING
2/4
4/8
100
100
3.8
3.8
A
1.2
1.2
kW
20
30
W
0,2
0,2
s
1,6
2,5
%
15
25
W
10
10
W
7.5/15
50
7.6
2.4
40
0,2
1,6
50
10

Hide quick links: