Step 8: Testing Your Installation

ELECTRICAL SHOCK HAZARD
The Inverter Enable button on the Freedom SW 230V and the optional
accessories do not disconnect DC or AC input power to the Freedom SW
230V.
Failure to follow these instructions can result in death or serious injury.
There are several tests to be performed for testing your
installation. These tests will verify that:
the Freedom SW 230V works in invert mode,
the Freedom SW 230V works in charge mode, and
the Freedom SW 230V works in AC bypass mode.
If the test fails at any point, go to "Step 7: Performing Checks
Prior to Initial Start-Up" on page 40 and go through the
checklist again to check the installation. Then perform the test
again. If the test fails again, see the troubleshooting section in
the Freedom SW 230V Sine Wave Inverter/Charger Owner's
Guide.
975-0697-01-01
XANBUS INTERFACE
STACKING
CLEAR FAULT
RESET
Figure 15 Freedom SW 230V Front Panel

Testing in Invert Mode

To test the Freedom SW 230V in invert mode, using a 100
watt light bulb as the test load:
1. Close the DC disconnect switch or the DC circuit breaker
to supply DC power to the Freedom SW 230V.
Wait for all the lights on the front panel to flash on and
off, indicating that the unit has successfully initialized (10
to 30 seconds).
Installing the Inverter/Charger
INVERTER
ENABLE
INVERTER
ENABLED
AC IN
FAULT
GEN
CHARGING WARNING
SUPPORT
41