Step 8: Testing Your Installation; Testing In Invert Mode - Xantrex Freedom SW 815-3012 Installation Manual

Freedom sw sine wave inverter/chargers
Hide thumbs Also See for Freedom SW 815-3012:
Table of Contents

Advertisement

Step 8: Testing Your Installation

ELECTRICAL SHOCK HAZARD
The Inverter Enable button on the Freedom SW and the optional
accessories do not disconnect DC or AC input power to the Freedom SW.
Failure to follow these instructions can result in death or serious
injury.
There are several tests to be performed for testing your installation. These
tests will verify that:
the Freedom SW works in invert mode,
the Freedom SW works in charge mode, and
the Freedom SW works in AC bypass mode.
If the test fails at any point, go to "Step 7: Performing Checks Prior to
Initial Start-Up" on page 40 and go through the checklist again to check the
installation. Then perform the test again. If the test fails again, see the
troubleshooting section in the Freedom SW Sine Wave Inverter/Charger
Owner's Guide.
97-0020-01-01
XANBUS INTERFACE
STACKING
CLEAR FAULT
RESET
Figure 16 Freedom SW Front Panel

Testing in Invert Mode

To test the Freedom SW in invert mode, using a 100 watt light bulb as
the test load:
1.
Close the DC disconnect switch or the DC circuit breaker to supply
DC power to the Freedom SW.
Wait for all the lights on the front panel to flash on and off, indicating
that the unit has successfully initialized (10 to 30 seconds).
If the light does not come on, make sure the voltage at the DC
terminals on the Freedom SW is correct, as described in "Step 7:
Performing Checks Prior to Initial Start-Up" on page 40.
Installing the Inverter/Charger
INVERTER
ENABLE
INVERTER
ENABLED
AC IN
FAULT
GEN
CHARGING WARNING
SUPPORT
41