Specifications - Ametek IntelliPoint RF RML Series Installation And Operating Instructions Manual

Point level switch with manual calibration/set point
Table of Contents

Advertisement

IntelliPoint RF RML Series
Section 6: Specifications
Technology:
Calibration:
Modes of
Operation:
Repeatability
Response Time:
Time Delay:
Ambient Electronics:
Storage Temperature: -40 to 85°C (-40 to 185°F)
Indicators:
Power supply:
Power consumption:
Relay Contacts:
Maximum
Contact Load:
Maximum
Switching Capacity:
Minimum
Contact Load (DC):
Housing (Electronics): Dual Compartment, powder-coated aluminum with two cable
Cable entry:
Ingress Protection:
Approvals Available:
RF/Capacitance
None
High and Low level
2mm (0.08 inch) conductive liquids
Less than 1 second
0 to 60 seconds forward and reverse acting.
-30 to 70°C (-28 to 158°F) KEMA. -40 to 70°C (-40 to 158°F)
FM (CSA pending).
LEDs:
Green-Power, Red-Relay 1, Red-Relay 2
Universal Supply
85 to 250 VAC
21 to 100 VDC auto-detecting w/o jumper changes
DC to 400 Hz
2 Watts Maximum
(2) SPDT
5A/30 VDC
5A/250 VAC
2000 VA/150 Watt
100 mA/12 VDC
0 to 200 mA / 12 VDC Optional
entries
M20 x 1.5 CENELEC
¾-inch NPT FM/CSA
IP66 NEMA 4X
Explosion-proof for Class I, Division 1, Groups A, B, C, and
D; Dust-Ignition proof for Class II, III, Division 1, Groups E,
F, and G; Non-incendiary for Class I, Division 2, Groups A,
B, C & D; Suitable for Class II, III, Groups F & G hazardous
outdoor Type 4X, IP66 (classified) locations with Intrinsically
Safe connections to Class I, II, III, Division 1, Groups A, B, C,
D, E, F, and G hazardous (classified) locations in accordance
with Control Drawing 420-0004-144-CD.