Over Range; Under Range; Testing Integral Cable - Ametek IntelliPoint RF RML Series Installation And Operating Instructions Manual

Point level switch with manual calibration/set point
Table of Contents

Advertisement

IntelliPoint RF RML Series
5.3
Testing Relay Circuits (continued)
5.4

Over Range

5.5

Under Range

5.6

Testing Integral Cable

Figure 5-3
Testing Integral Cable
Customer
M4 / 2.5mm Hex Drive
Connections
View
5
4
3
2
1
M3 / 2.5mm
Hex Drive
M5 / Slotted Drive
If relay #2 LED is flashing, instrument has detected that
uncovered sensing element capacitance exceeds limits of
transmitter. Consult factory for pad capacitor values and
instructions.
If relay #1 LED is flashing, instrument has detected that pad
capacitor value is toolarge. Consult factory for pad capacitor
values.
Center
Wire
Center
Wire
Center
Wire
25
#8-32 / Phillips-Slotted
Drive
6
7
8
3
4
NO
C
M3 / 2.5mm
Hex Drive
Figure 5.2
Relay Circuit Operation
Ohmmeter
0
Shield
Ohmmeter
0
Shield
Ohmmeter
0
Shield
Troubleshooting
5
6
7
8
NC
NO
C
NC
Shield
Center
Wire
Shield
Center
Wire
Shield
Center
Wire