Specifications - Ametek Drexelbrook IntelliPoint RF RNL Series Installation And Operating Instructions Manual

Point level switch
Table of Contents

Advertisement

RNLXX1 - IntelliPoint RF Series User's Manual
Section 5: Specifications
5.1

Specifications

Technology:
Calibration:
Modes of Operation:
Repeatability:
Response Time:
Time Delay:
Ambient Electronics:
Storage Temperature: -40 to 85°C (-40 to 185°F)
Indicators:
Self-Check:
Power Supply:
Power Consumption:
Relay Contacts:
Maximum
Contact Load:
Minimum
Contact Load (DC):
Housing (Electronics): Dual Compartment, Powder-Coated
Cable Entry:
Ingress Protection:
RF/ Capacitance
None
High and Low Level
2mm (0.08 inch) Conductive Liquids
Less than 1 Second
0 to 60 Seconds Forward & Reverse Acting
-30 to 70°C (-22 to 158°F) ATEX
-30 to 58°C (-22 to 136°F) IECEx
-40 to 70°C (-40 to 158°F) FM
LEDs: Green=Power, Red= Relay 1, Red= Relay 2
Continuous AutoVerify and Manual Certify
Universal Supply
85 to 250 VAC
21 to 100 VDC Auto-Detecting w/o Jumper Changes
DC to 400 Hz
2 Watts Maximum
(2) SPDT
5A/30 VDC/ 5A/250 VAC - Environmentally Sealed
100 mA/12 VDC
0 to 200 mA / 12 VDC Optional
Aluminum with Two Cable Entries
M20 x 1.5 ATEX/IECEx/ ¾-Inch NPT FM/FMc
IP66 NEMA 4X
32