Yamaha YX600S Service Manual page 249

Hide thumbs Also See for YX600S:
Table of Contents

Advertisement

~~~~~~~~~~~-L_1G_H_T_1_N_G_s_v_s_T_E_M_IELEcl ~I
OK
l
Low_ specific
gravity
•Recharge battery.
Charging Current:
1.2 amps/10 hrs
NOTE:
Replace the battery if:
•Battery voltage will not rise to a
specific value or bubbles fail to rise
even after many hours of charging.
• Sulfation of one or more cells occurs,
as indicated by the plates turning
white, or an accumulation of materi-
al exists in the bottom of the cell.
•Specific gravity readings after a long,
slow charge indicate on cell to be low-
er than the rest.
•Warpage or buckling of plates or in-
sulators is evident.
5. Main switch conduct check
•Disconnect main switch coupler (Brown,
Red, Blue).
•Connect Pocket Tester (YU-03112) to main
switch leads.
Tester (
+)
lead-+ Red lead
Tester (-) lead-+ Brown lead
Tester (
+)
lead-+ Red lead
Tester(-) lead-+Blue lead
NOTE:
Set tester selector to "Ox 1" position.
•Turn main switch to "ON" position and
check it for continuity.