Yamaha YX600S Service Manual page 240

Hide thumbs Also See for YX600S:
Table of Contents

Advertisement

I
ELEC
I
53
I
CHARGING SYSTEM
6-41
OK
l
Low_ specific
gravity
•Recharge battery.
Charging Current:
1.2 amps/10 hrs
NOTE:
Replace the battery if:
•Battery voltage will not rise to a
specific value or bubbles fail to rise
even after many hours of charging.
• Sulfation of one or more cells occurs,
as indicated by the plates turning
white, or an accumulation of materi-
ad exists in the bottom of the cell.
•Specific gravity readings after a long,
slow charge indicate on cell to be low-
er than the rest.
•Warpage or buckling of plates or in-
· sulators is evident.
5. Charging voltage test
•Connect Pocket Tester (YU-03112) to
battery.
NOTE:
~~~~~~~~~~~~~­
Set tester selector to "DC20V" position.
Tester ( +)
lead~Battery
( +) terminal
Tester(-)
lead~Battery
(-)terminal
•Start engine and accelerate to about 5,000
r/min.
•Measure charging voltage.
Charging Voltage:
14-15 V at 5,000 r/min