ELEC
I
s
I
CARBURETOR AIR VENT SYSTEM
6-71
Eyes: Flush with water for 15 minutes and
get prompt medical attention. Batteries
produce explosive gases. Keep sparks,
flame, cigarettes etc., away. Ventilate when
charging or using in an enclosed space. Al-
ways shield your eyes when working near
batteries.
KEEP OUT OF REACH OF CHILDREN.
OK
l
Low_ specific
gravity
•Recharge battery.
Charging Current:
1.2 amps/10 hrs
NOTE:
Replace the battery if:
•Battery voltage will not rise to a
specific value or bubbles fail to rise
even after many hours of charging.
•Sulfation of one or more cells occurs,
as indicated by the plates turning
white, or an accumulation of materi-
al exists in the bottom of the cell.
•Specific gravity readings after a long,
slow charge indicate on cell to be low-
er than the rest.
•Warpage or buckling of plates or in-
sulators is evident.