1-Bin Tray Unit (D574)
20. Connect the connectors of the harnesses [A]. Then route the harnesses [A] and the flat cable [B].
Finally, connect the connector of the flat cable [B] (
x 1,
x 4).
• The flat cable [B] should go through the ferrite cores [C].
• The harnesses [A] and the flat cable [B] should be routed under the harness [D] when these
are reconnected.
• Never connect the flat cable [B] obliquely. Otherwise, the scanner unit may be damaged.