5. System Maintenance
I/F Setting
Selects the remote service setting.
[0 to 2 / 2 / 1/step]
001
0: Remote service off
1: CSS remote service on
2: NRS remote service on
CE Call
Performs the CE Call at the start or end of the service.
[0 or 1 / 0 / 1/step]
002
0: Start of the service
1: End of the service
• This SP is activated only when SP 5816-001 is set to "2".
Function Flag
Enables or disables the remote service function.
003
[0 to 1 / 0 / 1/step]
0: Disabled, 1: Enabled
SSL Disable
Controls if RCG (Remote Communication Gate) confirmation is done by SSL during an
RCG send for the @Remote over a network interface.
007
[0 or 1 / 0 / 1/step]
0: Yes (SSL used)
1: No (SSL not used)
RCG Connect Timeout
Sets the length of time (seconds) for the time-out when the RCG (Remote Communication
008
Gate) connects during a call via the @Remote network.
[1 to 90 / 30 / 1 second/step]