012 Interval:Disp:FC
013 Corr(Short):FC
014 Corr(Mid):FC
3539
[Dev Agitating Time :Set]
001 Time
010 ON/OFF(by AbsHum)
011 AbsHum:1
012 AbsHum:2
013 AbsHum:3
014 AbsHum:4
015 AbsHum:5
016 AbsHum:6
021 AbsHum Threshold:1
022 AbsHum Threshold:2
023 AbsHum Threshold:3
024 AbsHum Threshold:4
025 AbsHum Threshold:5
Displays the page interval for job end process
control.
*ENG
[0 to 5000 / - / 1sheets/step]
Sets the correctin coeficient (Short) for job end
process control.
*ENG
[0.00 to 1.00 / 0.50 / 0.01/step]
Sets the correctin coeficient (Mid) for job end
process control.
*ENG
[0.00 to 1.00 / 1 / 0.01/step]
Sets the developer agitating time.
*ENG
[0 to 5000 / 10 / 1sec/step]
Sets on/off for relative humidity correction of
the developer agitating time.
*ENG
[0 or 1 / 1 / 1/step]
0:OFF, 1:ON
*ENG
[0 to 3000 / 0 / 1sec/step]
*ENG
[0 to 3000 / 0 / 1sec/step]
*ENG
[0 to 3000 / 5 / 1sec/step]
*ENG
[0 to 3000 / 5 / 1sec/step]
*ENG
[0 to 3000 / 5 / 1sec/step]
*ENG
[0 to 3000 / 5 / 1sec/step]
*ENG
[0.0 to 65.0 / 4.0 / 0.1g/m3/step]
*ENG
[0.0 to 65.0 / 8.0 / 0.1g/m3/step]
*ENG
[0.0 to 65.0 / 12.0 / 0.1g/m3/step]
*ENG
[0.0 to 65.0 / 16.0 / 0.1g/m3/step]
*ENG
[0.0 to 65.0 / 24.0 / 0.1g/m3/step]