6. Troubleshooting
Partial CMY Color Dots
Symptom
Unexpected dots of the same
color appear at irregular
intervals.
Dark Irregular Streaks on Prints
Symptom
Unexpected streaks appear at
irregular intervals.
CMY Color Irregular Streaks
Symptom
Unexpected streaks of the same
color appear at irregular
intervals.
Ghosting
Symptom
The same or similar image
appears two or more times.
They get weaker and weaker.
716
Possible cause
Defective PCDU
Defective image transfer belt
unit
Defective fusing unit
Possible cause
Defective image transfer belt
Possible cause
Defective PCDU
Defective image transfer belt
unit
Possible cause
Defective PCDU
Defective transfer unit
Necessary actions
Replace the PCDU.
Replace the image transfer belt
unit.
Replace the fusing unit.
Necessary actions
Replace the image transfer belt
unit.
Necessary actions
Replace the PCDU.
Replace the image transfer belt
unit.
Necessary actions
Replace the PCDU.