Ricoh Aficio MP C305SP Field Service Manual page 346

Gr-c1, machine codes: d117/d118
Hide thumbs Also See for Aficio MP C305SP:
Table of Contents

Advertisement

5. System Maintenance
Pre-idling Time
002
DFU
Specifies the fusing rotation time before executing SP1152-001.
Stop Time
003
DFU
Specifies the time for measuring the nip.
004
Feed Time
DFU
1153
[Low Temp. Start Up]
Temp.:Threshold Value1
001
Sepcifies the threshold temperature 1 for the warming up in the low temperature
condition.
Temp.:Threshold Value2
002
Sepcifies the threshold temperature 2 for the warming up in the low temperature
condition.
Temp.:Target
003
Sepcifies the target temperature for the warming up in the low temperature condition.
Temp.:Rotation Threshold Value1
005
Sepcifies the threshold temperature 1 for the warming up rotation in the low temperature
condition.
Time:Heat Storage Devision1
010
Sepcifies the execution time 1 for the warming up in the low temperature condition.
Time:Heat Storage Devision2
011
Sepcifies the execution time 2 for the warming up in the low temperature condition.
[Motor Speed Adjust]
1801
Adjusts the speeds of each motor.
001 transportM:Plain1/2
002 transportM:Thin
344
*ENG
[0 to 999 / 300 / 1sec/step]
*ENG
[0 to 100 / 20 / 1sec/step]
*ENG
[0 to 10000 / 8316 / 1msec/step]
*ENG
[-100 to 100 / -100 / 1deg/step]
*ENG
[-100 to 100 / -100 / 1deg/step]
*ENG
[-100 to 100 / -100 / 1deg/step]
*ENG
[-100 to 100 / -100 / 1deg/step]
*ENG
[0 to 1000 / 0 / 1sec/step]
*ENG
[0 to 1000 / 0 / 1sec/step]
*ENG
[-4.00 to 4.00 / 0.00 / 0.01%/step]
*ENG
[-4.00 to 4.00 / 0.00 / 0.01%/step]

Advertisement