5. System Maintenance
001 Lockout On/Off
002 Lockout Threshold
003 Cancellation On/Off
004 Cancellation Time
5414
[Access Mitigation]
001 Mitigation On/Off
002 Mitigation Time
5415
[Password Attack]
442
Switches on/off the lock on the local address
book account.
*CTL
[0 or 1 / 0 / -]
0: Off, 1: On
Sets a limit on the frequency of lockouts for
account lockouts.
*CTL
[1 to 10 / 5 / 1/step]
Determines whether the system waits the
prescribed time for input of a correct user ID and
password after an account lockout has
occurred.
*CTL
[0 or 1 / 0 / -]
0: Off (no wait time, lockout not cancelled)
1: On (system waits, cancels lockout if correct
user ID and password are entered.
Determines the length of time that the system
waits
for correct input of the user ID and password
after
*CTL
a lockout has occurred. This setting is used only
if
SP5413-3 is set to "1" (on).
[1 to 999 / 60 / 1 min./step]
Switches on/off masking of continuously used
IDs and passwords that are identical.
*CTL
[0 or 1 / 0 / -]
0: Off, 1: On
Sets the length of time for excluding continuous
access for identical user IDs and passwords.
*CTL
[0 to 60 / 15 / 1 min./step]