5. System Maintenance
008 Transmission Speed
011 WEP key Select
042 Fragment Thresh
043 11g CTS to Self
044 11g Slot Time
476
[0 x 00 to 0 x FF / 0 x FF to Auto / -]
0 x FF to Auto [Default]
0 x 11 - 55M Fix
0 x 10 - 48M Fix
0 x 0F - 36M Fix
0 x 0E - 18M Fix
0 x 0D - 12M Fix
*CTL
0 x 0B - 9M Fix
0 x 0A - 6M Fix
0 x 07 - 11M Fix
0 x 05 - 5.5M Fix
0 x 08 - 1M Fix
0 x 13 - 0 x FE (reserved)
0 x 12 - 72M (reserved)
0 x 09 - 22M (reserved)
Selects the WEP key.
[00 to 11 / 00 / 1 binary]
00: Key #1
*CTL
01: Key #2 (Reserved)
10: Key #3 (Reserved)
11: Key #4 (Reserved)
Adjusts the fragment threshold for the
IEEE802.11 card.
*CTL
[256 to 2346 / 2346 / 1]
This SP is displayed only when the
IEEE802.11 card is installed.
Determines whether the CTS self function is
turned on or off.
*CTL
[0 to 1 / 1 / 1] 0: Off, 1: On
This SP is displayed only when the
IEEE802.11 card is installed.
Selects the slot time for IEEE802.11.
*CTL
[0 to 1 / 0 / 1] 0: 20 um, 1: 9 um