No.
Type
-02
D
FGATE OFF error: Cy
-03
D
FGATE OFF error: Ma
-04
D
FGATE OFF error: Ye
• The PFGATE ON signal still asserts within 5 seconds after processing finish
timing for black (-01), cyan (-02), magenta (-03) or yellow (-04) color
writing.
• The PFGATE ON signal still asserts when the next job starts.
See SC 230 for troubleshooting details.
No.
Type
240
D
LD error: Bk or Cy
-01
-03
D
LD error: Ma or Ye
The BICU detects an LD error a few times consecutively when the LDB unit turns on
after LDB initialization.
• Worn-out LD
• Disconnected or broken harness of the LD
1. Replace the harness of the LD.
2. Replace the laser optics housing unit.
3. Replace the BICU.
No.
Type
260
C
Writing temperature thermistor error: Bk - Cy
-01
-03
C
Writing temperature thermistor error: Ma - Ye
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC Tables
643