6. Troubleshooting
No.
Type
CTL
841
D
No.
Type
CTL
842
C
No.
Type
CTL
850
B
No.
Type
CTL
853
B
No.
Type
CTL
854
B
680
Details (Symptom, Possible Cause, Troubleshooting Procedures)
EEPROM error 2: EEPROM read/write error
Mirrored data of the EEPROM is different from the original data in EEPROM.
Data in the EEPROM is overwritten for some reason.
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Flash ROM verification error
Verification error of the flash ROM on the controller board occurs.
Note:
- This SC is logged at 1st error detection.SC819 is issued at 2nd error detection.
- SC819 is issued at 2nd error detection.
• Defective flash ROM (controller board)
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Network I/F error
Inoperative
1. Turn the main switch off and on.
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Bluetooth device connection error
The Bluetooth interface unit was installed while the machine was turned on.
1. Turn off the main power switch, and then confirm that the Bluetooth interface
unit was installed correctly. Then turn on the main power switch again.
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Bluetooth device connection error
The Bluetooth interface unit was removed while the machine was turned on.
1. Turn off the main power switch, and then confirm that the Bluetooth interface
unit was installed correctly. Then turn on the main power switch again.