5. System Maintenance
Retransmission Ringing
Normally, it is best to allow unlimited time for certification and ID2 update requests, and
for the notification that the certification has been completed. However, RCG-M generates
174
charges based on transmission time for the customer, so a limit is placed upon the time
allowed for these transactions.
If these transactions cannot be completed within the allowed time, do this SP to cancel the
time restriction.
FAX TX Priority
This SP determines whether pushing the off-hook button will interrupt a RCG-M
transmission in progress to open the line for fax transaction. This SP can be used only if
187
SP5816 164 is set to "0".
[0 or 1/ 0 / - ]
0: Disable, 1: Enable
Manual Polling
200
Executes the manual polling.
Regist Status
Displays a number that indicates the status of the @Remote service device.
0: Neither the registered device by the external nor embedded RCG device is set.
1: The embedded RCG device is being set. Only Box registration is completed. In this
status, this unit cannot answer a polling request from the external RCG.
201
2: The embedded RCG device is set. In this status, the external RCG unit cannot answer a
polling request.
3: The registered device by the external RCG is being set. In this status the embedded
RCG device cannot be set.
4: The registered module by the external RCG has not started.
Letter Number
202
Allows entry of the number of the request needed for the RCG-N device.
Confirm Execute