005 Absolute Humidity: Thresh 3
006 Absolute Humidity: Thresh 4
007 Current Temp.: Display
Current Relative Humidity:
008
Display
Current Absolute Humidity:
009
Display
010 Previous Environmental: Display
011 Previous Temp.: Display
Previous Relative Humidity:
012
Display
Previous Absolute Humidity:
013
Display
2014
[Charge Control: Establishment]
001 Practice Interval: Power ON
002 Practice Interval: Printing
003 Judge Interval
004 Temp Condition
Changes the humidity threshold between
MM and MH. DFU
*ENG
[0.00 to 100.00 / 18.00 / 0.01 g/m
step]
Changes the humidity threshold between
MH and HH. DFU
*ENG
[0.00 to 100.00 / 24.00 / 0.01 g/m
step]
Displays the current temperature.
*ENG
[0 to 100 / - / 1 deg/step]
Displays the current relative humidity.
*ENG
[0 to 100 / - / 1%RH/step]
Displays the absolute humidity.
*ENG
[0.00 to 100.00 / - / 0.01 g/m
Displays the previous environmental
condition, which is measured in absolute
humidity.
*ENG
[1 to 5 / - / 1/step]
1: LL, 2: ML, 3: MM, 4: MH, 5: HH
Displays the previous temperature.
*ENG
[0 to 100 / - / 1 deg/step]
Displays the previous relative humidity.
*ENG
[0 to 100 / - / 1%RH/step]
Displays the previous absolute humidity.
*ENG
[0.00 to 100.00 / - / 0.01/step]
*ENG
[0 to 2000 / 500 / 1 page/step]
*ENG
[0 to 2000 / 0 / 1 page/step]
*ENG
[0 to 500 / 10 / 1 page/step]
*ENG
[0 to 99 / 35 / 1 deg/step]