5. System Maintenance
[Fan Control Off Mode Time Set]
1952
Specifies the time for fan control off mode.
001 -
[Extra Fan Control]
1953
Configures the settings of extra fan control.
Extra Fan Cooling State
001
Displays the extra fan cooling is On or Off.
Execution Temp. Threshold
006
Specifies the judgment temperature for the starting of extra fan execution.
Cancellation Temp. Threshold
007
Specifies the threshold temperature (the difference in value with the starting of extra fan
execution) for the cancellation of extra fan execution.
fan setting with or without
operation
008
Enables or disenables the control of extra fan execution control.
0: Disenable
1: Enable
-
1954
Fan low noise mode end temperature
001 Fan Half Speed Control
350
*ENG
[0 to 60 / 10 / 1min/step]
[0 or 1 / - / 1/step]
*ENG
Off, 1: On
*ENG
[0.0 to 100.0 / 42.0 / 0.1deg/step]
*ENG
[0.0 to 100.0 / 5.0 / 0.1deg/step]
*ENG
[0 or 1 / - / 1/step]
*ENG
[0 to 100 / 30 / 0.1deg/step]