Output Compare Unit - Atmel ATmega48PV Manual

8-bit microcontroller with 4/8/16/32k bytes in-system programmable flash
Table of Contents

Advertisement

15.5

Output Compare Unit

8025I–AVR–02/09
Figure 15-2. Counter Unit Block Diagram
DATA BUS
TCNTn
Signal description (internal signals):
count
direction
clear
clk
Tn
top
bottom
Depending on the mode of operation used, the counter is cleared, incremented, or decremented
at each timer clock (clk
selected by the Clock Select bits (CS22:0). When no clock source is selected (CS22:0 = 0) the
timer is stopped. However, the TCNT2 value can be accessed by the CPU, regardless of
whether clk
is present or not. A CPU write overrides (has priority over) all counter clear or
T2
count operations.
The counting sequence is determined by the setting of the WGM21 and WGM20 bits located in
the Timer/Counter Control Register (TCCR2A) and the WGM22 located in the Timer/Counter
Control Register B (TCCR2B). There are close connections between how the counter behaves
(counts) and how waveforms are generated on the Output Compare outputs OC2A and OC2B.
For more details about advanced counting sequences and waveform generation, see
Operation" on page
149.
The Timer/Counter Overflow Flag (TOV2) is set according to the mode of operation selected by
the WGM22:0 bits. TOV2 can be used for generating a CPU interrupt.
The 8-bit comparator continuously compares TCNT2 with the Output Compare Register
(OCR2A and OCR2B). Whenever TCNT2 equals OCR2A or OCR2B, the comparator signals a
match. A match will set the Output Compare Flag (OCF2A or OCF2B) at the next timer clock
cycle. If the corresponding interrupt is enabled, the Output Compare Flag generates an Output
Compare interrupt. The Output Compare Flag is automatically cleared when the interrupt is exe-
cuted. Alternatively, the Output Compare Flag can be cleared by software by writing a logical
one to its I/O bit location. The Waveform Generator uses the match signal to generate an output
according to operating mode set by the WGM22:0 bits and Compare Output mode (COM2x1:0)
bits. The max and bottom signals are used by the Waveform Generator for handling the special
cases of the extreme values in some modes of operation
Figure 15-3
shows a block diagram of the Output Compare unit.
ATmega48P/88P/168P/328P
count
clear
Control Logic
direction
bottom
top
Increment or decrement TCNT2 by 1.
Selects between increment and decrement.
Clear TCNT2 (set all bits to zero).
Timer/Counter clock, referred to as clk
Signalizes that TCNT2 has reached maximum value.
Signalizes that TCNT2 has reached minimum value (zero).
). clk
can be generated from an external or internal clock source,
T2
T2
TOVn
(Int.Req.)
clk
Tn
Prescaler
in the following.
T2
("Modes of Operation" on page
TOSC1
T/C
Oscillator
TOSC2
clk
I/O
"Modes of
149).
146

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ATmega48PV and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF