Figure 23. Location of the reset button
4 Using a pen or a similar pointed object, momentarily press the reset button on the reset adapter
assembly to reboot the AP and CM, or press and hold the reset button for 1-4 seconds to
reboot, or 5-10 seconds to reset the AP and CM to factory defaults.
5 Using a torque screwdriver or wrench, tighten the access plug to 1.7N.m or 15in-lbs as described
in
Re-Installing an Access Plug or Hardline
You have completed resetting the AP and CM to their factory default settings and/or rebooting the
AP and CM.

Remotely Rebooting and Factory Resetting the AP

NOTE Before starting this procedure, you must first obtain the related MIBs from Ruckus Wireless.
Contact your authorized Ruckus Wireless sales representative or Ruckus Wireless Support. Visit
http://support.ruckuswireless.com/contacts
for Ruckus Wireless Support contact information.
1 Connect the administrative computer to the same network as the T811-CM.
2 Start your MIB browser.
3 Load the Ruckus Wireless MIBs onto the MIB browser.
4 In the MIB browser, specify the IP address of the T811-CM AP. (You can obtain this information
from the DHCP server on the network.)
5 Find the OID 1.3.6.1.4.1.25053.3.1.4.7.3 (ruckusZF7761CMControlLED). (***XXX*** need correct
MIB)
6 Then do the following:
• To soft reset the AP, set the value to 10 (softResetAP).
• To hard set the AP, set the value to 11 (powerCycleAP).
• To factory-reset the AP, set the value to 12 (factoryResetAP).
You have completed remotely rebooting or factory-resetting the access point using SNMP.