Powering the T811-CM with POC

60 to 90 VAC POC is used when the T811-CM is mounted on a cable strand and powered via an F-
type coaxial cable connected to the HFC cable plant.
1 Remove the power jumper from the power tap to remove AC power out of the power tap.
2 Insert the F-type coaxial cable that is connected to the HFC cable plant to the F-type connector
on the T811-CM. Power is supplied through a power passing tap on the CATV coax. The tap is
connected to F-type connector on the T811-CM as shown in
3 Finger tighten the coaxial cable connector and then tighten to 3.4N.m (30in-lbs).
4 Plug the power jumper back into the power tap to restore AC power out of the power tap.
5 When the T811-CM receives power, its LEDs flash on and off as it goes through a power-on self
test and then receives its AP and CM configurations from the cable operator.
NOTE Normally, the T811-CM receives its AP and CM configurations from the cable operator.
This means that the installer does not need to manually configure either the AP or the CM part of the
T811-CM.
6 Wait until the T811-CM PWR, CM DS, CM US, and ONLINE LEDs stop flashing and then remain
on.
You have verified that the T811-CM is powered. Continue with
with an RF Power Meter
T811-CM AP Installation Guide, 800-71436-001 Rev A
(Optional).
Installing the T811-CM
Deploying the T811-CM
Figure
5.
Checking the T811-CM Signal Level
26