5. PARAMETERS

5.2.3 Network setting parameters ([Pr. PN_ _ ])

No./symbol/
Setting
name
digit
PN02
Set the time until [AL. 86.1 Network communication error 1] is detected.
CERT
Setting "0" disables the detection of [AL. 86.1 Network communication error 1].
Communication
This parameter can be used only when CC-Link IE Field Network Basic is set.
error detection
time
Setting range: 0 to 1000
PN08
_ _ _ x Command interface selection
*NOP8
Set the command interface in the positioning mode. The setting of this digit is
disabled in the position control mode, speed control mode, torque control mode, and
Function
profile mode.
selection N-8
0: General-purpose interface
1: Communication interface
_ _ x _ For manufacturer setting
_ x _ _
x _ _ _ Communication function selection
0: Ethernet communication (CC-Link IE field network Basic, SLMP, and
1: RS-485 communication (Modbus RTU)
Communications other than selected communication function are unavailable.
PN10
Set the time until [AL. 86.4 Network communication error 4] is detected.
*CONN
Setting "0" disables the detection of [AL. 86.4 Network communication error 4].
Ethernet
This parameter is enabled with SLMP and Modbus/TCP.
communication
The detection of [AL. 86.4] starts when SLMP or Modbus/TCP is received for the first
time-out
time. When an alarm is detected and then reset, the detection stops and will restart
selection
upon receipt of the next SLMP or Modbus/TCP.
This parameter can be used on servo amplifiers with software version A4 or later.
This parameter cannot be used when Modbus RTU is set.
Setting range: 0 to 60
PN11
Set the 1st octet of the IP address in decimal.
*IPAD1
Set the IP address assigned by the network administrator.
IP address
When SLMP command (IPAdressSet) is received, the setting of the first octet is
setting 1
written to this parameter.
Refer to table 5.1 for the relation between the setting value of the identification
number setting rotary switch and the parameter setting value.
This parameter cannot be used when Modbus RTU is set.
Setting range: 0 to 255
Table 5.1 Relation between IP address setting and identification number setting rotary switch
Identification number
setting rotary switch
(SW1/SW2)
00h
01h to FFh
Modbus/TCP)
1st octet
The setting value of [Pr. PN11] is used.
2nd octet
The setting value of [Pr. PN12] is used.
3rd octet
The setting value of [Pr. PN13] is used.
4th octet
The setting value of [Pr. PN14] is used.
1st octet
The setting value of [Pr. PN11] is used.
2nd octet
The setting value of [Pr. PN12] is used.
3rd octet
The setting value of [Pr. PN13] is used.
The setting value of the identification number setting
4th octet
rotary switch (SW1/SW2) is used.
Function
IP address
5 - 8
Initial
value
[unit]
1000
[ms]
0h
0h
0h
0h
0
[s]
192