Mitsubishi Electric MR-JE-C Series Instruction Manual page 22

Melser i/o-je ethernet interface, servo amplifier
Table of Contents

Advertisement

2. CC-Link IE Field Network Basic/SLMP
(supporting the position/speed/torque control mode, profile mode, and home position return mode)
Master station → Servo amplifier (RWwn)
Device No.
Index
(Note)
RWwn00
6060
Modes of operation
RWwn01
6040
Controlword
RWwn02
2D01
Control DI 1
RWwn03
2D02
Control DI 2
RWwn04
2D03
Control DI 3
RWwn05
607A
Target position
RWwn06
RWwn07
60FF
Target velocity
RWwn08
RWwn09
2D20
Velocity limit value
RWwn0A
RWwn0B
6071
Target torque
RWwn0C
6081
Profile velocity
RWwn0D
RWwn0E
6083
Profile acceleration
RWwn0F
RWwn10
6084
Profile deceleration
RWwn11
RWwn12
6087
Torque slope
RWwn13
RWwn14
60E0
Positive torque limit value
RWwn15
60E1
Negative torque limit value
RWwn16
RWwn17
60B8
Touch probe function
RWwn18
60F2
Positioning option code
RWwn19
2D05
Control DI 5
RWwn1A
RWwn1B
RWwn1C
RWwn1D
RWwn1E
RWwn1F
Note. "n" depends on the station No. setting.
Table 2.2 RWwn/RWrn mapping
Device No.
Device
RWrn00
RWrn01
RWrn02
RWrn03
RWrn04
RWrn05
RWrn06
RWrn07
RWrn08
RWrn09
RWrn0A
RWrn0B
RWrn0C
RWrn0D
RWrn0E
RWrn0F
RWrn10
RWrn11
RWrn12
RWrn13
RWrn14
RWrn15
RWrn16
RWrn17
RWrn18
RWrn19
RWrn1A
RWrn1B
RWrn1C
RWrn1D
RWrn1E
RWrn1F
2 - 5
Servo amplifier → Master station (RWrn)
Index
(Note)
6061
Modes of operation display
6041
Statusword
6064
Position actual value
606C
Velocity actual value
60F4
Following error actual value
6077
Torque actual value
2D11
Status DO 1
2D12
Status DO 2
2D13
Status DO 3
2A42
Current alarm 2
60B9
Touch probe status
60BA
Touch probe pos1 pos value
60BB
Touch probe pos1 neg value
2C12
External Input signal display1
Device