Overview - Emerson Rosemount 3051S Series Reference Manual

Scalable pressure, flow, and level solution with hart protocol
Hide thumbs Also See for Rosemount 3051S Series:
Table of Contents

Advertisement

Reference Manual
00809-0100-4801, Rev HA
Section 7
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 101
User interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 102
Process Intelligence and Plugged Impulse Line Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 104
Loop Integrity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 119
Diagnostic Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 123
Variable Logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 126
Process Alerts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 129
Service Alerts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 131
Device Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 133
Rosemount 333 Hart Tri-Loop Configuration with Advanced Diagnostics . . . . . . . . . . . . . . . . . . page 135
7.1

Overview

The Advanced HART
Instrumentation and takes full advantage of the scalable architecture. The Rosemount 3051S
SuperModule
mounted in the Plantweb
communicates with the SuperModule and produces standard 4-20 mA and HART outputs while adding
advanced diagnostic card ability.
Note
When a new SuperModule is connected to the diagnostic electronics board for the first time, the
transmitter will be in alarm state until lower and upper range values are specified.
The Advanced HART Diagnostics Suite is designated by the option code "DA2" in the model number. All
options can be used with DA2 except the following:
F
OUNDATION
Wireless (output code X)
Quick Connect (housing code 7J)
Junction Box (housing code 2A, 2B, 2C, 2J)
Remote display (housing code 2E, 2F, 2G, 2M)b
The HART Diagnostic transmitter has seven distinct diagnostic functions that can be used separately or
in conjunction with each other to detect and alert users to conditions that were previously undetectable
and to provide powerful troubleshooting tools.
Advanced HART Diagnostic Suite
Advanced HART
®
Diagnostic Suite is an extension of the Rosemount
Platform generates the pressure measurement while the diagnostic electronics board is
housing and plugs into the top of the SuperModule. The electronics board
Fieldbus Protocol (output code F)
Advanced HART Diagnostic Suite
®
Diagnostic Suite
3051S Series of
October 2018
101

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents